1 / 3
HR Gas boiler - EF PRO 56/230 - 227 liters 54.2 kW
- Current bid
- Status
Lot specifications
- Quantity
- 1
- Margin
- No
- Model
- EF PRO 56/230
- Weight
- 242kg
- Length
- 71cm
- Width
- 71cm
- Height
- 144cm
Description
Technical Specifications:
Rated Power (kW): 54.2
Rated Load (Hi) kW: 52.7
Rated Load (hs) kW: 58.6
Yield (upper value): 92%
Gas Category: I 2L, I2H, I3p
Gas input pressure (mbar): 20/25/37
Peak gas consumption (m3/hour): 6.23
Type of layout flue gas outlet: B23, C13, C33, C53, C63
Flue gas diameter (concentric, mm): 100/150
Emissions of Nitrogen oxides (NOx mg/kWh): 44
Electrical connection (Volts/Hz): 230/50-60
Adjustable Water Temperature (°C): 32 - 82
Water operating pressure (min. - max. bar): 1.0 - 10.0
Dimensions (H x W x D, mm): 1448 x 718 x 718
Mounting weight (kg): 242
Volume Tank (liters): 227
Tap capacity (l/hour):
Continuous (80°C): 660
Continuous (65°C): 840
Continuous (60°C): 930
Continuous (40°C): 1550
1st hour (65°C): 1000
1st hour (60°C): 1090
1st hour (40°C): 1710
Warm-up time (min):
T=70°C: 22
T=55°C: 17
T=50°C: 16
T=30°C: 9
Additional details
Er is geen herroepingsrecht.
De minimumleeftijd voor het bezoeken van de kijk- en ophaaldagen is 18 jaar. Bezoekers moeten zich kunnen identificeren.
Tijdens de ophaaldag is een vorkheftruck beschikbaar. De maximale hefcapaciteit bedraagt 2 ton.
Gebruik van de vorkheftruck geschiedt geheel op eigen risico. Daarnaast kunnen zich wachttijden voordoen.